3010 Spring Industrial Drive, Powder Springs, GA 30127

VCS Condensate Return Systems

Customizable Product

CALL FOR DETAILS

 

 


 

RECEIVERS

  • Cast iron, rectangular receivers are available with 15 to 110 gallon capacities.
  • Heavy duty, welded, rust resistant, copper bearing steel receivers are available in rectangular or cylindrical configurations with capacities ranging from 21 to 1,000 gallons.

Consult your local representative for custom engineered receivers and rust resistant linings.

Lockwood VCS pumping systems are available in simplex, duplex, triplex or quadruplex configurations from 1,000 to 100,000 sq. ft. EDR capacities.  Discharge pressures from 10-40 psi are available on units equipped with 1750 RPM motors; 15-75 psi on 3500 RPM units. Standard selections use 1750 RPM motors only on 10 psi applications.

 


 

VJ PUMPS

  • 1/2 thru 2 HP
  • 3500 RPM (Discharge pressures are 15, 20, 30, 40 or 50 psi)

MOTOR TYPES AVAILABLE:

  • Open drip proof (ODP) only
  • Single phase, 115/230 V, 60 Hz
  • Three phase, 208 or 230/460 V, 60 Hz.

VC PUMPS

  • 1/3 thru 15 HP
  • 1725 RPM (Discharge pressure are 10, 15, or 20 psi)
  • 3500 RPM (Discharge pressures are 30 to 75 psi)

MOTOR TYPES AVAILABLE:

  • Open drip proof (ODP)
  • Totally enclosed fan cooled (TEFC)
  • Explosion proof
  • Single phase, 115/230 V, 60 Hz
  • Three phase, 208 or 230/460 V, 60 Hz

VE PUMPS*

  • 3/4 thru 2 HP
  • 1750 RPM (Discharge pressure are 20, 25 or 30 psi)

MOTOR TYPES AVAILABLE:

  • Open drip proof (ODP)
  • Totally enclosed fan cooled (TEFC)
  • Explosion proof
  • Single phase, 115/230 V, 60 Hz
  • Three phase, 200 V, 60 Hz
  • Three phase, 230/460 V, 60 Hz

VA PUMPS*

  • 3, 5 or 7 1/2 HP
  • 1750 RPM (Discharge pressure are 30 or 40 psi)

MOTOR TYPES AVAILABLE:

  • Open drip proof (ODP)
  • Totally enclosed fan cooled (TEFC)
  • Explosion proof
  • Three phase, 200 V, 60 Hz
  • Three phase, 230/460 V, 60 Hz
*Contact factory for recommended selections.

CENTRIFUGAL PUMPS

Four centrifugal models are available in a large selection of sizes to meet your specific application requirements: VC, VJ, VE and VA.

The pumps are bolted directly to the receiver to provide a compact, efficient design. Their close-coupled, centrifugal design with bronze enclosed type impeller assures smooth, efficient water passage. A mechanical seal, rated to a maximum temperature of 220°F, is vented to the receiver to assure adequate lubrication at all times.

All standard selections are rated for condensate temperatures up to 200°F. Consult factory for higher temperature applications, as some pumps are available that have low NPSH capability. These pumps have advanced impeller and volute design that can provide true 2ˈ NPSH capacity without using additional impellers and parts required by other manufacturers.

Designed for long-life, low maintenance and reliable service, the pumps are easily serviceable if necessary. Parts subject to normal wear are readily accessible. Impeller and seal can be serviced without distributing piping or electrical connections.

All pumps are close-coupled to heavy duty, ball bearing electric motors. Fractional horsepower single phase motors have built-in thermal overload protection.

To help you determine the appropriate pump type for your application, specifications for each of the four types are described in the next paragraphs. Refer to selection table for additional pumping system performance data.

TYPICAL PUMP CROSS-SECTION

 


 

SELECTION DATA

All selections listed below at 10 psi are 1750 RPM – all others, 3500 RPM except 801 1/2 and 1001 1/2

MAX SQ. FT.
EDR
RECEIVER
SIZE
PUMP CAP.
GPM
DISCHARGE
PRESSURE
AT PUMP
PUMP
TYPE
PUMP
SIZE
MOTOR
HP
RETURN
PIPE
SIZE
DISCHARGE
PIPE SIZE
10VCS-11
15-11 ½½
20-12½2″
1530-13½CAST IRON
1,000or1 ½40VJS-1411 ¼”
2150-151 ½2 ½”
60-162STEEL
75-17 ½3
10VCS-21
15-21 ½½2″
1520-22½CAST IRON1 ¼”
2,000or330VJS-23½
2140-2412 ½”
50-251 ½STEEL1 ½”
60VCS-2621 ¼”
75-27 ½3
10VCS-41
15-41 ½½2″
1520-42½CAST IRON1 ¼”
4,000or630VJS-43½
2140-4412 ½”
50-451 ½STEEL1 ½”
60VCS-4621 ¼”
75-47 ½3
10VCS-61
15-61 ½½2″
1520-62½CAST IRON1 ¼”
6,000or930VJS-63½
2140-6412 ½”
50-652STEEL1 ½”
60VCS-6621 ¼”
75-67 ½3
10VCS-81
15-81 ½½2″
1520-82½CAST IRON1 ¼”
8,000or1230VJS-83½
2140-8412 ½”
50-852STEEL1 ½”
60VCS-8621 ¼”
75-87 ½3
10VCS-1011 ½”
15-101 ½½2″
1520-102½CAST IRON1 ¼”
10,000or1530VJS-103¾
2140-10412 ½”
50-1052STEEL1 ½”
60VCS-10621 ¼”
75-107 ½3
10VCS-1511 ½”
15-151 ½½2″
20-152½CAST IRON1 ¼”
15,0002122 ½30VJS-153¾
40-15412 ½”
50-1552STEEL1 ½”
60VCS-15631 ¼”
75-157 ½3
10VCS-2011 ½”
15-201 ½½2 ½”
20-202¾CAST IRON1 ¼”
20,000453030VJS-2031
40-2041 ½3″1 ½”
50-2052STEEL
60VCS-20631 ¼”
75-207 ½5
10VCS-251½1 ½”
15-251 ½½2 ½”
20-252¾CAST IRON1 ¼”
25,0004537 ½30VJS-2531
40-2541 ½3″
50-2553STEEL1 ½”
60VCS-25631 ¼”
75-257 ½51 ½”
10VCS-301½
15-301 ½12 ½”
20-3021CAST IRON1 ½”
30,000454530VJS-3031 ½
40-30423″
50-3053STEEL
60VCS-30631 ½”
75-307 ½7 ½
10VCS-401¾
15-401 ½1 ½3″
20VJS-4021 ½CAST IRON1 ½”
40,000656030-4031 ½
40-40433″
50VCS-4055STEEL
60-4065
75-407 ½7 ½
10VCS-50112″
15-501 ½1 ½3″
20VJS-5021 ½CAST IRON1 ½”
50,000657530-5032
40-50433″
50VCS-5055STEEL
60-5065
75-507 ½7 ½
10VCS-6511 ½2″
15-651 ½24″1 ½”
20VJS-6522CAST IRON
65,00011097 ½30-6533
40VCS-65454″2″
50-6555STEEL
60-6567 ½
10-8011 ½
15-801 ½25″
20-8023CAST IRON
80,00011012030VCS-80352″
40-80455″
50-8057 ½STEEL
60-8067 ½
10-10011 ½
15-1001 ½25″
20-10025CAST IRON
100,00011015030VCS-100352″
40-10047 ½5″
50-10057 ½STEEL
60-100610

 


 

····································································  Condensate Receivers  ····································································

dimensional DATA

VC, VJ AND VE PUMPS WITH CAST IRON OR STEEL RECTANGULAR RECEIVERS